User Tools

Site Tools


equipment:ups2

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
equipment:ups2 [2016/03/21 15:15]
walter
equipment:ups2 [2021/05/02 21:36] (current)
Line 9: Line 9:
 Model: ​ \\ Model: ​ \\
 Series: \\ Series: \\
- +Datasheet{{:​equipment:​smart2600rm2u_tripp_lite_datasheet_212247541444983440121.pdf}}
- +
- +
-===== Quick Info ===== +
- +
-^ Output ​                                    ​^ ​                                                                                  ^ +
-| Output Volt Amp Capacity (VA)              | 2600                                                                              | +
-| Output kVA Capacity (kVA)                  | 2.6                                                                               | +
-| Output Watt Capacity (Watts) ​              | 1920                                                                              | +
-| Output kW Capacity (kW)                    | 1.92                                                                              | +
-| Power Factor ​                              | 0.87                                                                              | +
-| Nominal Output Voltage(s) Supported ​       | 110V; 115V; 120V                                                                  | +
-| Nominal Voltage Details ​                   | 120v nominal output in battery mode                                               | +
-| Frequency Compatibility ​                   | 60 Hz                                                                             | +
-| Output Voltage Regulation (Line Mode)      | -14%, +6%                                                                         | +
-| Output Voltage Regulation (Battery Mode)   | +/- 5%                                                                            | +
-| Output Receptacles ​                        | (4) 5-15R; (4) 5-15/20R; (1) L5-20R ​                                              | +
-| Load Management Receptacles ​               | Two switchable single-outlet 5-15R load banks                                     | +
-| Output Circuit Breakers ​                   | 15A breaker protects 5-15R, 20A breaker protects 5-15/20R, L5-20R is unbreakered ​ | +
-| Output AC Waveform (AC Mode)               | Sine wave                                                                         | +
-| Output AC Waveform (Battery Mode)          | Pure Sine wave                                                                    | +
- +
- +
-^ Input                                ^               ^ +
-| Rated input current (Maximum Load)   | 16A           | +
-| Nominal Input Voltage(s) Supported ​  | 120V AC       | +
-| UPS Input Connection Type            | 5-20P         | +
-| UPS Input Cord Length (ft.)          | 10            | +
-| Recommended Electrical Service ​      | 20A 120V      | +
-| Input Phase                          | Single-Phase ​ | +
- +
-^ Battery ​                                    ​^ ​                                                                                                                                         ^ +
-| Full Load Runtime (min.) ​                   | 4.6 min. (1920w) ​                                                                                                                        | +
-| Half Load Runtime (min.) ​                   | 12.9 min. (960w) ​                                                                                                                        | +
-| Expandable Battery Runtime ​                 | Extended runtime supported via optional external battery packs                                                                           | +
-| External Battery Pack Compatibility ​        | BP48V24-2U(limit 1); BP48V60RT-3U(multi-pack compatible);​ BP48V27-2US(multi-pack compatible) ​                                            | +
-| DC System Voltage (VDC)                     | 48                                                                                                                                       | +
-| Battery Recharge Rate (Included Batteries) ​ | Less than 4.5 hours from 10% to 90% (typical, full load discharge) ​                                                                      | +
-| Internal UPS Replacement Battery Cartridge ​ | [[http://​www.tripplite.com/​2U-UPS-Replacement-48VDC-Battery-Cartridge-1-Set-of-4-for-Select-Tripp-Lite-SmartPro-UPS~RBC94-2U|RBC94-2U]] ​ | +
-| Battery Access ​                             | Front panel battery access door                                                                                                          | +
-| Battery Replacement Description ​            | Hot-swappable,​ user replaceable batteries ​                                                                                               | +
-| Expandable Runtime ​                         | Yes                                                                                                                                      |+
equipment/ups2.txt · Last modified: 2021/05/02 21:36 (external edit)