-====== UPS 1 ====== 
  
-UPS 1 is the second rack mount UPS in the [[equipment:​main server rack][ along with [[equipment:​UPS 0]] and [[equipment:​UPS 2]].  
- 
-===== Basic Info ===== 
- 
- 
-Manufacturer:​ Tripp-Lite \\ 
-Model: SMART2600RM2U \\ 
-Series:​AGSM4842 \\ 
- 
-[[http://​www.tripplite.com/​line-interactive-sine-wave-ups-system-2.6kva-snmp-2u-rack-tower-usb-rs232-epo-extended-runtime-120v~SMART2600RM2U/​|Product Page]] 
- 
-===== Quick Info ===== 
- 
-^ Output ​                                    ​^ ​                                                                                  ^ 
-| Output Volt Amp Capacity (VA)              | 2600                                                                              | 
-| Output kVA Capacity (kVA)                  | 2.6                                                                               | 
-| Output Watt Capacity (Watts) ​              | 1920                                                                              | 
-| Output kW Capacity (kW)                    | 1.92                                                                              | 
-| Power Factor ​                              | 0.87                                                                              | 
-| Nominal Output Voltage(s) Supported ​       | 110V; 115V; 120V                                                                  | 
-| Nominal Voltage Details ​                   | 120v nominal output in battery mode                                               | 
-| Frequency Compatibility ​                   | 60 Hz                                                                             | 
-| Output Voltage Regulation (Line Mode)      | -14%, +6%                                                                         | 
-| Output Voltage Regulation (Battery Mode)   | +/- 5%                                                                            | 
-| Output Receptacles ​                        | (4) 5-15R; (4) 5-15/20R; (1) L5-20R ​                                              | 
-| Load Management Receptacles ​               | Two switchable single-outlet 5-15R load banks                                     | 
-| Output Circuit Breakers ​                   | 15A breaker protects 5-15R, 20A breaker protects 5-15/20R, L5-20R is unbreakered ​ | 
-| Output AC Waveform (AC Mode)               | Sine wave                                                                         | 
-| Output AC Waveform (Battery Mode)          | Pure Sine wave                                                                    | 
- 
- 
-^ Input                                ^               ^ 
-| Rated input current (Maximum Load)   | 16A           | 
-| Nominal Input Voltage(s) Supported ​  | 120V AC       | 
-| UPS Input Connection Type            | 5-20P         | 
-| UPS Input Cord Length (ft.)          | 10            | 
-| Recommended Electrical Service ​      | 20A 120V      | 
-| Input Phase                          | Single-Phase ​ | 
- 
-^ Battery ​                                     ^                                                                                               ^ 
-| Full Load Runtime (min.) ​                    | 4.6 min. (1920w) ​                                                                             | 
-| Half Load Runtime (min.) ​                    | 12.9 min. (960w) ​                                                                             | 
-| Expandable Battery Runtime ​                  | Extended runtime supported via optional external battery packs                                | 
-| External Battery Pack Compatibility ​         | BP48V24-2U(limit 1); BP48V60RT-3U(multi-pack compatible);​ BP48V27-2US(multi-pack compatible) ​ | 
-| DC System Voltage (VDC)                      | 48                                                                                            | 
-| Battery Recharge Rate (Included Batteries) ​  | Less than 4.5 hours from 10% to 90% (typical, full load discharge) ​                           | 
-| Internal UPS Replacement Battery Cartridge ​  | RBC94-2U ​                                                                                     | 
-| Battery Access ​                              | Front panel battery access door                                                               | 
-| Battery Replacement Description ​             | Hot-swappable,​ user replaceable batteries ​                                                    | 
-| Expandable Runtime ​                          | Yes                                                                                           | 
equipment/ups2.txt ยท Last modified: 2021/05/02 21:36 (external edit)