- | ====== UPS 2 ====== | ||
- | UPS 1 is the second rack mount UPS in the [[equipment:main server rack]] along with [[equipment:ups1]] and [[equipment:UPS 3]]. | ||
- | |||
- | ===== Basic Info ===== | ||
- | |||
- | |||
- | Manufacturer: Tripp-Lite \\ | ||
- | Model: \\ | ||
- | Series: \\ | ||
- | |||
- | |||
- | |||
- | ===== Quick Info ===== | ||
- | |||
- | ^ Output ^ ^ | ||
- | | Output Volt Amp Capacity (VA) | 2600 | | ||
- | | Output kVA Capacity (kVA) | 2.6 | | ||
- | | Output Watt Capacity (Watts) | 1920 | | ||
- | | Output kW Capacity (kW) | 1.92 | | ||
- | | Power Factor | 0.87 | | ||
- | | Nominal Output Voltage(s) Supported | 110V; 115V; 120V | | ||
- | | Nominal Voltage Details | 120v nominal output in battery mode | | ||
- | | Frequency Compatibility | 60 Hz | | ||
- | | Output Voltage Regulation (Line Mode) | -14%, +6% | | ||
- | | Output Voltage Regulation (Battery Mode) | +/- 5% | | ||
- | | Output Receptacles | (4) 5-15R; (4) 5-15/20R; (1) L5-20R | | ||
- | | Load Management Receptacles | Two switchable single-outlet 5-15R load banks | | ||
- | | Output Circuit Breakers | 15A breaker protects 5-15R, 20A breaker protects 5-15/20R, L5-20R is unbreakered | | ||
- | | Output AC Waveform (AC Mode) | Sine wave | | ||
- | | Output AC Waveform (Battery Mode) | Pure Sine wave | | ||
- | |||
- | |||
- | ^ Input ^ ^ | ||
- | | Rated input current (Maximum Load) | 16A | | ||
- | | Nominal Input Voltage(s) Supported | 120V AC | | ||
- | | UPS Input Connection Type | 5-20P | | ||
- | | UPS Input Cord Length (ft.) | 10 | | ||
- | | Recommended Electrical Service | 20A 120V | | ||
- | | Input Phase | Single-Phase | | ||
- | |||
- | ^ Battery ^ ^ | ||
- | | Full Load Runtime (min.) | 4.6 min. (1920w) | | ||
- | | Half Load Runtime (min.) | 12.9 min. (960w) | | ||
- | | Expandable Battery Runtime | Extended runtime supported via optional external battery packs | | ||
- | | External Battery Pack Compatibility | BP48V24-2U(limit 1); BP48V60RT-3U(multi-pack compatible); BP48V27-2US(multi-pack compatible) | | ||
- | | DC System Voltage (VDC) | 48 | | ||
- | | Battery Recharge Rate (Included Batteries) | Less than 4.5 hours from 10% to 90% (typical, full load discharge) | | ||
- | | Internal UPS Replacement Battery Cartridge | [[http://www.tripplite.com/2U-UPS-Replacement-48VDC-Battery-Cartridge-1-Set-of-4-for-Select-Tripp-Lite-SmartPro-UPS~RBC94-2U|RBC94-2U]] | | ||
- | | Battery Access | Front panel battery access door | | ||
- | | Battery Replacement Description | Hot-swappable, user replaceable batteries | | ||
- | | Expandable Runtime | Yes | |