+ | ====== MegaraidCLI ====== | ||
+ | |||
+ | **Page Under Construction, is based off of the megaraid pdf on the main page** | ||
+ | |||
+ | ---- | ||
+ | |||
+ | The MegaRaid cli utility is used to talk to LSI MegaRaid controllers, such as the one in the PowerEdge 2950 which is re-branded by Dell as the perc5. The utility exists in the AUR (Arch User Repository) and is installed in /opt. | ||
+ | |||
+ | ====== Command Flags ====== | ||
+ | |||
^ Flag ^ Description ^ | ^ Flag ^ Description ^ | ||
| ¦ |Specifies “or,” meaning you can choose between options. | | | ¦ |Specifies “or,” meaning you can choose between options. | | ||
Line 11: | Line 21: | ||
|{ } | Indicates that the parameters are grouped and that they must be given at the same time. | | |{ } | Indicates that the parameters are grouped and that they must be given at the same time. | | ||
- | ^Command ^Description | + | ====== Get Adapter Info ====== |
- | | MegaCli -AdpAllinfo -aN ¦-a0,1,2¦-aALL | Displays information about the controller, including cluster state, BIOS, alarm, firmware version, BIOS version, battery charge counter value, rebuild rate, bus number/device number, present RAM, memory size, serial number of the board, and SAS address. | | + | |
- | + | ||
- | ====== Set Controller Properties ====== | + | |
<code> | <code> | ||
- | MegaCli –AdpSetProp {CacheFlushInterval –val}|{RebuildRate -val}| | + | MegaCli -AdpAllinfo -aN ¦-a0,1,2¦-aALL |
- | {PatrolReadRate –val}|{BgiRate –val}|{CCRate –val}| {ReconRate –val}| | + | |
- | {SpinupDriveCount –val}|{SpinupDelay –val}|{CoercionMode –val} | | + | |
- | {ClusterEnable –val}|{PredFailPollInterval –val}| {BatWarnDsbl –val}| | + | |
- | {EccBucketSize –val}|{EccBucketLeakRate –val}|{AbortCCOnError | + | |
- | –val}|AlarmEnbl | AlarmDsbl | AlarmSilence |{SMARTCpyBkEnbl –val} | | + | |
- | -AutoDetectBackPlaneDsbl | -CopyBackDsbl | -LoadBalanceMode | -aN| | + | |
- | -a0,1,2|-aALL | + | |
</code> | </code> | ||
+ | Displays information about the controller, including cluster state, BIOS, alarm, firmware version, BIOS version, battery charge counter value, rebuild rate, bus number/device number, present RAM, memory size, serial number of the board, and SAS address. | ||
+ | ====== Controller Properties ====== | ||
+ | |||
+ | <code> | ||
CacheFlushInterval: Cache flush interval in seconds. Values: 0 to 255. | CacheFlushInterval: Cache flush interval in seconds. Values: 0 to 255. | ||
+ | |||
RebuildRate: Rebuild rate. Values: 0 to 100. | RebuildRate: Rebuild rate. Values: 0 to 100. | ||
+ | |||
PatrolReadRate: Patrol read rate. Values: 0 to 100. | PatrolReadRate: Patrol read rate. Values: 0 to 100. | ||
+ | |||
BgiRate: Background initilization rate. Values: 0 to 100. | BgiRate: Background initilization rate. Values: 0 to 100. | ||
+ | |||
CCRate: Consistency check rate. Values: 0 to 100. | CCRate: Consistency check rate. Values: 0 to 100. | ||
+ | |||
ReconRate: Reconstruction rate. Values: 0 to 100. | ReconRate: Reconstruction rate. Values: 0 to 100. | ||
+ | |||
SpinupDriveCount: Max number of drives to spin up at one time. Values: 0 to 255. | SpinupDriveCount: Max number of drives to spin up at one time. Values: 0 to 255. | ||
+ | |||
SpinupDelay: Number of seconds to delay among spinup groups. Values: 0 to 255. | SpinupDelay: Number of seconds to delay among spinup groups. Values: 0 to 255. | ||
+ | |||
CoercionMode: Drive capacity Coercion mode. Values: 0 - None, 1 - 128 Mbytes, | CoercionMode: Drive capacity Coercion mode. Values: 0 - None, 1 - 128 Mbytes, | ||
2 - 1 Gbytes. | 2 - 1 Gbytes. | ||
+ | |||
ClusterEnable: Cluster is enabled or disabled. Values: 0 - Disabled, 1 - Enabled. | ClusterEnable: Cluster is enabled or disabled. Values: 0 - Disabled, 1 - Enabled. | ||
+ | |||
PredFailPollInterval: Number of seconds between predicted fail polls. Values: | PredFailPollInterval: Number of seconds between predicted fail polls. Values: | ||
0 to 65535. | 0 to 65535. | ||
+ | |||
BatWarnDsbl: Disable warnings for missing battery or missing hardware. | BatWarnDsbl: Disable warnings for missing battery or missing hardware. | ||
+ | |||
Values: 0 - Enabled, 1 - Disabled. | Values: 0 - Enabled, 1 - Disabled. | ||
+ | |||
EccBucketSize: Size of ECC single-bit-error bucket. Values: 0 to 255. | EccBucketSize: Size of ECC single-bit-error bucket. Values: 0 to 255. | ||
+ | |||
EccBucketLeakRate: Leak rate (in minutes) of ECC single-bit-error bucket. | EccBucketLeakRate: Leak rate (in minutes) of ECC single-bit-error bucket. | ||
+ | |||
Values: 0 to 65535. | Values: 0 to 65535. | ||
+ | |||
AbortCCOnError: | AbortCCOnError: | ||
+ | |||
AlarmEnbl: Set alarm to Enabled. | AlarmEnbl: Set alarm to Enabled. | ||
+ | |||
AlarmDsbl: Set alarm to Disabled. | AlarmDsbl: Set alarm to Disabled. | ||
+ | |||
AlarmSilence: Silence an active alarm. | AlarmSilence: Silence an active alarm. | ||
+ | |||
SMARTCpyBkEnbl: Enable copyback operation on Self-Monitoring Analysis and | SMARTCpyBkEnbl: Enable copyback operation on Self-Monitoring Analysis and | ||
Reporting Technology (SMART) errors. Copyback is initiated when the first SMART | Reporting Technology (SMART) errors. Copyback is initiated when the first SMART | ||
error occurs on a drive that is part of a virtual drive. | error occurs on a drive that is part of a virtual drive. | ||
+ | |||
AutoDetectBackPlaneDsbl: Detect automatically if the backplane has been | AutoDetectBackPlaneDsbl: Detect automatically if the backplane has been | ||
disabled. | disabled. | ||
+ | |||
CopyBackDsbl: Disable or enable the copyback operation. | CopyBackDsbl: Disable or enable the copyback operation. | ||
+ | |||
LoadBalanceMode: Disable or enable the load balancing mode. | LoadBalanceMode: Disable or enable the load balancing mode. | ||
+ | </code> | ||
+ | ===== Set Properties ===== | ||
+ | |||
+ | <code> | ||
+ | MegaCli –AdpSetProp {CacheFlushInterval –val}|{RebuildRate -val}| | ||
+ | {PatrolReadRate –val}|{BgiRate –val}|{CCRate –val}| {ReconRate –val}| | ||
+ | {SpinupDriveCount –val}|{SpinupDelay –val}|{CoercionMode –val} | | ||
+ | {ClusterEnable –val}|{PredFailPollInterval –val}| {BatWarnDsbl –val}| | ||
+ | {EccBucketSize –val}|{EccBucketLeakRate –val}|{AbortCCOnError | ||
+ | –val}|AlarmEnbl | AlarmDsbl | AlarmSilence |{SMARTCpyBkEnbl –val} | | ||
+ | -AutoDetectBackPlaneDsbl | -CopyBackDsbl | -LoadBalanceMode | -aN| | ||
+ | -a0,1,2|-aALL | ||
+ | </code> | ||
+ | ===== Get Properties ===== | ||
+ | |||
+ | <code> | ||
+ | MegaCli –AdpGetProp CacheFlushInterval | RebuildRate | PatrolReadRate| | ||
+ | BgiRate | CCRate | ReconRate | SpinupDriveCount | SpinupDelay | | ||
+ | CoercionMode | PredFailPollInterval | ClusterEnable | BatWarnDsbl | | ||
+ | EccBucketSize | EccBucketLeakRate | EccBucketCount | AlarmDsply -aN| | ||
+ | -a0,1,2|-aALL | ||
+ | </code> | ||
+ | |||
+ | ===== Set Factory Defaults ===== | ||
+ | <code> | ||
+ | MegaCli -AdpFacDefSet -aN|-a0,1,2|-aALL | ||
+ | </code> | ||
+ | |||
+ | ===== Set Time and Date on Controller ===== | ||
+ | <code> | ||
+ | MegaCli –AdpSetTime yyyymmdd HH:mm:ss -aN|-a0,1,2|-aALL | ||
+ | </code> | ||
+ | |||
+ | ===== Display Time and Date on Controller ===== | ||
+ | <code> | ||
+ | MegaCli –AdpGetTime -aN | ||
+ | </code> | ||
+ | |||
+ | ===== Patrol Read Controller Properties ===== | ||
+ | |||
+ | A Patrol Read scans the system for possible drive errors that could | ||
+ | lead to drive failure, then takes action to correct the errors. | ||
+ | The goal is to protect data integrity by detecting drive failure before the failure can | ||
+ | damage data. The corrective actions depend on the virtual drive | ||
+ | configuration and the type of errors. Patrol Read affects performance; the | ||
+ | more iterations there are, the greater the impact. | ||
+ | |||
+ | ==== Set Patrol Read Options ==== | ||
+ | |||
+ | <code> | ||
+ | MegaCli –AdpPR –Dsbl|EnblAuto|EnblMan|Start|Stop|Info -aN| | ||
+ | -a0,1,2|-aALL | ||
+ | </code> | ||
+ | <code> | ||
+ | -Dsbl: Disables Patrol Read for the selected controller(s). | ||
+ | -EnblAuto: Enables Patrol Read automatically for the selected controller(s). | ||
+ | This means Patrol Read will start automatically after the controller initialization is | ||
+ | complete. | ||
+ | -EnblMan: Enables Patrol Read manually for the selected controller(s). This means | ||
+ | that Patrol Read does not start automatically; it has to be started manually by | ||
+ | selecting the Start command. | ||
+ | -Start: Starts Patrol Read for the selected controller(s). | ||
+ | -Stop: Stops Patrol Read for the selected controller(s). | ||
+ | -Info: Displays the following Patrol Read information for the selected controller(s): | ||
+ | * Patrol Read operation mode | ||
+ | * Patrol Read execution delay value | ||
+ | * Patrol Read status | ||
+ | </code> | ||
+ | |||
+ | ==== Set Patrol Read Delay Interval ==== | ||
+ | Sets the time between Patrol Read iterations. | ||
+ | |||
+ | <code></code> | ||
+ | |||